Toshiba FS-1650 Cash Register User Manual


 
– 31 –
EO1-11113
6) Backup Data Update Process
(This is a process required when the backup data stored in the backup master terminal (BM) is
not updated properly due to an error.)
The method processing backup error is selected according to the program option setting.
Even if the automatic data copy operation is selected, data copy can be performed manu-
ally.
Automatic data copy (program option)
When the backup error flag is on (or turned on), the master terminal (M) automatically
sends to the backup master terminal (BM) the file in which the error has occurred, and
updates the backup data.
Manual data copy (program option)
The backup data is updated by the manual operations of the operator.
* When the backup data is being updated, inquiries from terminals may result in a “MASTER
IS BUSY” error.
* When a “MASTER IS BUSY” error occurs, clear the error using the [C] key.
Then, update the backup data again after the master job (backup process) is complete.
* Only the files with the backup error flag turned on are sent to the backup master terminal
(BM) to update the backup data.
* When the master job is being done on the master terminal (M) ([RTR] key is turned on),
backup data is not checked or updated.
* If the backup error flag is on when the master job is complete on the master terminal (M)
([RTR] key is turned off; the IN-LINE lamp is off), manual data copy becomes compulsory.
7) Manual Copy of Backup Data
OPERATION ON MASTER TERMINAL: Mode Lock : Z and IN-LINE
Lamp illuminated
900 [AT/TL]
MBM
Backup data
Response