Toshiba GD-1160 Fax Machine User Manual


 
GD-1210/1250/1270/1160/1260 © 2006 - 2011 TOSHIBA TEC CORPORATION All rights reserved
SELF-DIAGNOSIS MODE
2 - 12
Code
Adjust-
ment
Function Setting
Default
ASM AUS HKG USA DEU GBR ITA BEL NDL
13-
123
CML
hold
time
after
dialing
Pause after
dialing
0: 0 ms
1: 10 ms
¦
255:2550 ms
100 100 100 100 100 100 100 100 100
13-
125
Dial
informa-
tion
(Line 1)
Sets the defini-
tion of the DP
dial.
Normal: n
Shift: n+1
Reverse: 10-n
n=Dial No.
0: Normal
1: Shift
2: Reverse
000000000
13-
127
Internal
retry
When dialing is
interrupted
because any of
the settings for
DTC/LCC is not
satisfied during
redialing, that
redialing is
ignored since it
is considered
as an internal
retry.
0: OFF
1: ON
000011000
13-
128
Redial-
ing
counter
Sets the num-
ber of redial-
ings.
0: No retry
1: 1 redialing
¦
14: 14 redial-
ings
524534335
13-
129
Time for
a pause
(Line 1)
Sets the time
for a pause
when it is
inserted
between the
dial numbers.
0: 0 sec
1: 1 sec
2: 2 sec
3: 4 sec
4: 3.3 sec
5: 10 sec
422422320
13-
132
Inter-
digit
pause
(Line 1)
Sets the interval
between digits
for DP dialing.
0: 900 ms
1: 550 ms
2: 700 ms
3: 800 ms
002303322
13-
135
Redial-
ing inter-
val
(Line 1)
Sets the interval
between redial-
ings.
0: Default
(3 min)
1: 1 min
¦
15: 15 min
313100322
11/10