Toshiba GD-1160 Fax Machine User Manual


 
GD-1210/1250/1270/1160/1260 © 2006 - 2011 TOSHIBA TEC CORPORATION All rights reserved
SELF-DIAGNOSIS MODE
2 - 22
Code
Adjust-
ment
Function Setting
Default
ASM AUS HKG USA DEU GBR ITA BEL NDL
13-
226
DTC fre-
quency
(PABX)
(Line 2)
Sets the dial
tone frequency
to be detected
for the PABX.
0: 300-600 Hz
1: 300-650 Hz
2: 390-550 Hz
3: 400-450 Hz
4: 350-480 Hz
5: 300-500 Hz
000011111
13-
227
DTC
time
(PABX)
(Line 2)
Sets the time
for a tone
sounds to be
determined as
dial tone for the
PABX.
0: 2 sec
1: 800 ms
2: 400 ms
3: 1 sec
4: 1.3 sec
5: 1.8 sec
6: 2.5 sec
7: 150 ms
000622222
13-
228
LCC
allowed
gaps
(PABX)
(Line 2)
Sets the inter-
ruption time for
the PABX to be
ignored during
LCC.
0: OFF
1: 50 ms
2: 100 ms
3: 200 ms
000033333
13-
229
DTC
allowed
gaps
(PABX)
(Line 2)
Sets the inter-
ruption time for
the PABX to be
ignored during
DTC.
0: OFF
1: 320 ms
2: 160 ms
3: 240 ms
111111111
13-
230
DTC/
LCC for
PABX
(Line 2)
Selects which is
to be used for
the PABX, DTC
or LCC.
0: BZT (DTC/
LCC)
1: LCC 5 sec
2: DTC only
3: FRN (LCC/
DTC)
4: DTC (JPN&
USA)
5: NO
DTC&LCC
555555555
13-
231
DTC
time out
(PABX)
(Line 2)
Sets how long
the dial tone
detection is per-
formed.
0: 20 sec
1: 10 sec
2: 8 sec
3: 15 sec
4: 3.3 sec
000111111
13-
232
BTC fre-
quency
(Line 2)
Sets the busy
tone frequency
to be detected
for the PSTN
and PABX.
0: Not
detected
1: 300-600 Hz
2: 350-550 Hz
3: 300-500 Hz
4: 300-700 Hz
000111111
13-
236
Dial T1
timer
(Line 2)
Sets the time to
wait for a
response from
the receiver
after dialing is
completed.
0: 60 sec
1: 35 sec
2: 90 sec
3: 55 sec
4: 115 sec
030322222
11/10