Toshiba MA-1595-1 Series Cash Register User Manual


 
3. HARDWARE DESCRIPTION
EO1-11152
3.1 Operator Display Indications of Master-Satellite System
3- 1
3. HARDWARE DESCRIPTION
3.1 Operator Display Indications of Master-Satellite System
Display Indications during In-line Services
The followings are displayed in the 16-digit dot windows, 10-digit 7-segment window, and IN-LINE Lamp of
the Operator Display panel during in-line services.
< Master Terminal >
• IN-LINE Lamp
1) Illuminated during RTR declaration “ON”
2) Extinguished during RTR declaration “OFF”
3) Blinking during ULL operations
• Mode Indication
5 4 3 2 1
RTR/SET Mode:
RTR/X Mode:
RTR/Z Mode:
< Satellite Terminals or Backup Master Terminal >
• IN-LINE Lamp
1) Illuminated during “Hold” condition
2) Extinguished after completing in-line services
3) Blinking during in-line services
Error Messages
The following table shows the Error Codes and Messages to be displayed on in-line terminals, in addition to
those displayed on Standalone ECRs.
IN-LINE ERROR CODE AND MESSAGE TABLE
(to be added to the table for the Standalone Level)
Error Message
(Standard Setting)
Cause of Error
FILE BUSY A designated file is already occupied by other terminal.
IRC CONNECT ERR
Transmission cannot be executed due to the connection error (Disconnection of
the line, or Master Terminal’s power is OFF, etc.)
MASTER IS BUSY An inquiry file is being used.
PLEASE BACK UP RTR Declaration cannot be canceled due to the Backup Error
TRANS BUFF FULL Satellite Transaction Buffer is full.
P
X
Z
(
()
)
TL ST
DPT X
Number of ECRs unserviced
Illuminated
ECR No. now serviced at the time
of collecting read/reset data
Mode Indication
In-line Job No.
Blink