10.2 Holding Registers
Drive
Reg. #
(hex)
Title Function
Max
(hex:dec)
Min
(hex:dec)
Run Mode
Modify
A
B
0000
8000
AU1
Automatic acceleration and
deceleration time
1 0 Yes
A
B
0001
8001
AU2
Automatic torque boost 3 0 No
A
B
0002
8002
AU3
Automatic environment
setting
2 0 No
A
B
0003
8003
CMOD
Command mode selection 1 0 Yes
A
B
0004
8004
FMOD
Frequency setting mode
selection
2 0 Yes
A
B
0005
8005
FMSL
FM terminal function
selection
1 0 Yes
A
B
0006
8006
FM
Connected meter adjustment FF:255 0 Yes
A
B
0007
8007
tYP
Standard setting mode
selection
6 0 No
A
B
0008
8008
Fr
Forward/reverse selection
(panel)
1 0 Yes
A
B
0009
8009
ACC
Acceleration time #1 (s) 8CA0:3600 A:1.0 Yes
A
B
0010
8010
dEC
Deceleration time #1 (s) 8CA0:3600 A:1.0 Yes
A
B
0011
8011
FH
Maximum frequency 7D00:320.0 BB8:30.0 No
A
B
0012
8012
UL
Upper limit frequency
FH
32:0.5 Yes
A
B
0013
8013
LL
Lower limit frequency
UL
0:0.0 Yes
A
B
0014
8014
vL
Base frequency 7D00:320.0 9C4:25.0 Yes
A
B
0015
8015
Pt
V/F pattern 3 0 No
A
B
0016
8016
vb
Voltage boost BB8:30.0 0 Yes
A
B
0017
8017
OLM
OL selection 7 0 Yes
A
B
0018
8018
Sr1
Preset speed 1
UL LL
Yes
A
B
0019
8019
Sr2
Preset speed 2
UL LL
Yes
A
B
0020
8020
Sr3
Preset speed 3
UL LL
Yes
A
B
0021
8021
Sr4
Preset speed 4
UL LL
Yes
A
B
0022
8022
Sr5
Preset speed 5
UL LL
Yes