Toshiba MDB-100 Network Card User Manual


 
31
10.3 Write-Only Coils
Coil # S7 ASD Function OFF ON
31 Command source Local Network
30 Frequency command source Local Network
29 Fault reset N/A Reset
28 Emergency OFF command N/A Trip “E
27 Coast stop command N/A Coast stop
26 Run / stop command Stop Run
25 Forward / reverse selection Forward Reverse
24 Jog command N/A Jog
23
DC injection braking N/A
DC injection
command
22 Accel / decel #1/#2 selection #1 #2
21 Reserved -- --
20 Reserved -- --
19 Preset speed 4 OFF ON
18 Preset speed 3 OFF ON
17 Preset speed 2 OFF ON
Drive B
16 Preset speed 1 OFF ON
15 Command source Local Network
14 Frequency command source Local Network
13 Fault reset N/A Reset
12 Emergency OFF command N/A Trip “E
11 Coast stop command N/A Coast stop
10 Run / stop command Stop Run
9 Forward / reverse selection Forward Reverse
8 Jog command N/A Jog
7
DC injection braking N/A
DC injection
command
6 Accel / decel #1/#2 selection #1 #2
5 Reserved -- --
4 Reserved -- --
3 Preset speed 4 OFF ON
2 Preset speed 3 OFF ON
1 Preset speed 2 OFF ON
Drive A
0 Preset speed 1 OFF ON