Toshiba MDB-100 Network Card User Manual


 
30
Trip Data Codes
Display Data Trip Type
nErr
0000 No trip
OC1
0001 Overcurrent during acceleration
OC2
0002 Overcurrent during deceleration
OC3
0003 Overcurrent during constant-speed run
OCL
0004 Load-end short circuit trip during start-up
OCA
0005 Phase short circuit
0006 reserved
0007 reserved
EPH1
0008 reserved
EPH0
0009 Loss of output phase
OP1
000A Overvoltage during acceleration
OP2
000B Overvoltage during deceleration
OP3
000C Overvoltage during constant-speed run
OL1
000D Inverter overload trip
OL2
000E Motor overload trip
OLr
000F DBR overload
OH
0010 Overheat trip
E
0011 Emergency stop
EEP1
0012 EEPROM fault: write error
0013 reserved
0014 reserved
Err2
0015 RAM fault
Err3
0016 ROM fault
Err4
0017 CPU fault
Err5
0018 Communication interruption error
0019~0024 reserved
OCr
0025 Dynamic braking resistor trip
0026~0027 reserved
Etn
0028 Auto-tuning error
EtYP
0029 Inverter typeform error