Toshiba MDB-100 Network Card User Manual


 
27
Drive
Reg. #
(hex)
Title Function
Max
(hex:dec)
Min
(hex:dec)
Run Mode
Modify
A
B
0292
8292
F292
Preset speed 13
UL LL
Yes
A
B
0293
8293
F293
Preset speed 14
UL LL
Yes
A
B
0294
8294
F294
Preset speed 15
UL LL
Yes
A
B
0300
8300
F300
PWM carrier frequency (kHz) * 16:2.2 Yes
A
B
0301
8301
F301
Auto-restart (motor speed
search)
3 0 Yes
A
B
0302
8302
F302
Regeneration power ride-
through control
1 0 Yes
A
B
0303
8303
F303
Retry selection: number of
times
A:10 0 Yes
A
B
0304
8304
F304
Regenerative braking
selection
1 0 Yes
A
B
0305
8305
F305
Overvoltage stall protection 1 0 Yes
A
B
0306
8306
F306
Output voltage adjustment 78:120 0 Yes
A
B
0307
8307
F307
Line voltage compensation 1 0 No
A
B
0400
8400
F400
Auto-tuning 2 0 No
A
B
0401
8401
F401
Slip frequency gain FF:255 0 Yes
A
B
0402
8402
F402
Motor constant 1: R1 gain FF:255 0 No
A
B
0403
8403
F403
Motor constant 2: R2 gain FF:255 0 No
A
B
0404
8404
F404
Motor constant 3: M gain FF:255 0 No
A
B
0405
8405
F405
Load inertia 3 0 Yes
A
B
0406
8406
F406
Auto torque boost no load
current
1E:30 0 Yes
A
B
0407
8407
F407
Auto torque boost maximum
boost
1E:30 0 Yes
A
B
0500
8500
F500
Acceleration time #2 8CA0:3600 1:0.1 Yes
A
B
0501
8501
F501
Deceleration time #2 8CA0:3600 1:0.1 Yes
A
B
0502
8502
F502
Acceleration & deceleration
pattern #1
2 0 Yes
A
B
0503
8503
F503
Acceleration & deceleration
pattern #2
2 0 Yes
A
B
0504
8504
F504
Acceleration & deceleration
pattern #1 & #2
1 0 Yes