Xantrex Technology XW4548-120/240-60 Power Supply User Manual


 
The XW Automatic Generator Start
975-0239-01-01 5–9
Installing the XW Automatic Generator Start
Installation
Overview
Installing the XW Automatic Generator Start involves the following steps:
1. Mounting the unit.
2. Connecting the wiring harness to:
the generator (page 5–12)
thermostats (optional) (page 5–13)
external shutdown switch (optional) (page 5–13)
external ON/OFF switch and LED (optional) (page 5–14)
3. Connecting the wiring harness to the 20-contact connector on the XW Automatic
Generator Start.
4. Connecting the XW Automatic Generator Start to the XW System Control Panel and
other network-enabled devices (page 5–16).
Figure 5-8
XW Automatic Generator Start External Connections
Wiring harness (connection
to generator, thermostats,
and external switches)
Network cables to other
Xanbus-enabled devices
20-contact
connector
Network ports
Important:
Because each installation varies according to the location, the
type of generator, and the overall complexity of the Xanbus system, these
instructions can offer only general guidelines for the many installation options
available.
WARNING: Shock Hazard
Before installing the XW Automatic Generator Start as part of a pre-existing
Xanbus system, put the system in Standby in order to disable the electrical
operation of networked devices. See the Automatic Generator Start Owner’s
Guide for instructions on putting the System in Standby.