XW Solar Charge Controller Installation
4–16 975-0239-01-01
3. On the Advanced Settings menu, select Copy From, then select the XW Solar Charge
Controller you want to copy from. You should select the unit with the device number
that matches the first unit you configured.
4. Press Enter.
The settings are automatically copied from the selected unit.
5. Uncover the PV array and/or apply power with the disconnect or selector switch.
The XW Solar Charge Controller starts up in sleep mode and waits for a short period to
determine that the input voltage is greater than the output voltage. After the input voltage
exceeds the output voltage by the required margin for 10 seconds, the unit begins
operating.
Note: The Copy From command will not give you any indication that it has completed
its task. However, you can quickly check for yourself that the charger settings you have
chosen have been copied properly by viewing some of the settings you originally
configured.