Zebra S-Series User’s Guide 9
Figure 1
$&3RZHU)XVH5HSODFHPHQW
A user-replaceable AC power fuse is located just above the power
ON/OFF switch (see Figure 1). For a 115 VAC installation, the
replacement fuse is a 3AG Fast Blow style rated at 5 Amp/250VAC. For a
230 VAC installation, the fuse is the same style but rated at 3 Amp/250
VAC. Make sure the fuse you use is correct for the voltage source.
Note: Before replacing the fuse, turn the AC power switch OFF and
unplug the AC power cable.
1. To replace the fuse, insert the tip of a flatblade screwdriver into the
slot in the end of the fuse holder end cap.
2. Press in slightly on the end cap and turn the screwdriver slightly
counterclockwise. This disengages the end cap from the fuse holder
and allows you to remove the fuse.
3. To install a new fuse, remove the old fuse and insert the new fuse into
the fuse holder.
4. Push the end cap in slightly, then insert the tip of a flatblade
screwdriver into the slot in the end cap and turn clockwise to engage it.