Zebra Technologies TTP 8000 Printer User Manual


 
Default Parameter Settings
Serial Interface Set-up
74
P1003638-003 TTP 8000 Technical Manual 10/19/2009
Serial Interface Set-up
Stores the communication speed on the serial interface.
Selects if 7-bit ASCII, or 8-bit, is used on the serial interface.
<
Select what parity to use on the serial interface.
1
96 Default
Baud Rate
24 Min
11 Max
<ESC>&P<1><24> 2400 bps
<ESC>&P<1><48> 4800 bps
<ESC>&P<1><96> 9600 bps
<ESC>&P<1><19> 19200 bps
<ESC>&P<1><38> 38400 bps
<ESC>&P<1><57> 57600 bps
<ESC>&P<1><11> 115200 bps
Note • If you set an invalid value, the baud rate will return to the previous value.
2
8Default
Data Bits
7 Min
8Max
<ESC>&P<2><8> 8-bits (characters 0-255)
<ESC>&P<2><7> 7-bits (characters 0-127)
Note • In 7-bit mode you can not print graphic, read status or set parameters because no
value can ever be greater than 127.
3
0Default
Parity
0 Min
2Max
<ESC>&P<3><0> No parity
<ESC>&P<3><1> Odd parity
<ESC>&P<3><2> Even parity