FEED Key and PAUSE Key Self Test
Pressing these two keys at the same time, while turning the Power ON,
temporarily resets the Printer Configuration to the factory default val-
ues. These values will be active until Power is turned OFF. Whenever
the printer is reset to factory defaults, a Media Calibration procedure must
be performed immediately.
MODE Key Self Test
This test places the printer in the Communications Diagnostics Mode.
In this mode, the printer prints the ASCII characters and their corre-
sponding hexadecimal values for any data received from the host com-
puter. A typical printout from this test is shown in Figure 3.5.
Note: This label will be inverted when printed.
PAUSE Key and CANCEL Key Test
This test prints a maximum of 500 Head Test labels. Each label back-
feeds prior to printing and feeds forward to the rest position after print-
ing. A serialized number prints on each label. Press the PAUSE key or
turn the printer power OFF to stop printing. The labels look like the
oneinFigure3.3exceptthataserializednumberwillprintoneachla-
bel.
3-12 Zebra S-Series User’s Guide
Figure 3.5 Results of Communications Diagnostic Test