Prestige 623ME-T User’s Guide
19-4 SNMP Configuration
19.4 SNMP Traps
The Prestige will send traps to the SNMP manager when any one of the following events occurs:
Table 19-2 SNMP Traps
TRAP # TRAP NAME DESCRIPTION
1 coldStart (defined in RFC-1215) A trap is sent after booting (power on).
2 warmStart (defined in RFC-1215) A trap is sent after booting (software reboot).
3 linkDown (defined in RFC-1215) A trap is sent when the port is down.
4 linkUp (defined in RFC-1215) A trap is sent when the port is up.
5 authenticationFailure (defined in
RFC-1215)
A trap is sent to the manager when receiving any SNMP
get or set requirements with wrong community (password).
6 whyReboot (defined in ZYXEL-
MIB)
A trap is sent with the reason of restart before rebooting
when the system is going to restart (warm start).
6a For intentional reboot : A trap is sent with the message "System reboot by user!" if
reboot is done intentionally, (for example, download new
files, CI command "sys reboot", etc.).
The following table maps the physical port and encapsulation to the interface type.
Table 19-3 Ports and Interface Types
PHYSICAL PORT/ENCAP INTERFACE TYPE
LAN port(s) enet0
Wireless port enet1
PPPoE encap pppoe
1483 encap mpoa
Ethernet encap enet-encap
PPPoA ppp