3.6.10 AUTOSCAN TIME
Accessed from menu: GLOBAL PREFERENCES
Settings: DISABLED; 2, 5, 7, 10, 15, 20, 30 SECONDS
The autoscan time defines the length of time that the SmartView will display video
from an autoscanned computer before changing to the next computer. If the
DISABLED setting is chosen then no autoscan functions will be available.
3.6.11 OSD DWELL TIME
Accessed from menu: GLOBAL PREFERENCES
Settings: 1, 2, 3, 5, 10 SECONDS
After a successful computer channel change the SmartView will display a
confirmation message for a few seconds. The length of time that this confirmation
message dwells on the screen may be changed. Options are 1, 2, 3, 5 & 10 secs.
3.6.12 USER TIMEOUT
Accessed from menu: GLOBAL PREFERENCES
Settings: 2, 5, 10, 30 SECONDS; 1, 5, 10 MINUTES
When two users are connected to the same computer only one can have access at
any one time. When no keyboard or mouse data has been received from the active
user port for the user timeout period the SmartView will allow other users to access
the computer. The new port then becomes the active port until it too times out. To
avoid confusion between users it is desirable to set the timeout period to be
sufficiently long so that user's work is not needlessly interrupted by other users and
sufficiently short to ensure good overall system efficiency. The user timeout value
also controls the timeout between the local and remote access points on user ports
1 and 3.
3.6.13 RS232 Mouse Type
Accessed from menu: GLOBAL PREFERENCES
Settings: INTELLIMOUSE, 2 BUTTON, 3 BUTTON
These setting control the type of RS232 mouse that the SmartView reports to
computers. All the necessary conversions are dealt with automatically with the
SmartView. The IntelliMouse setting sends four byte mouse reports to the
computers and is therefore very slightly more sluggish than the others that send
three byte mouse reports. RS232 mice are almost always more sluggish than PS/2
types because the data rate is much slower.