ADTRAN 1000 Network Card User Manual


 
18 64179008APL1-5A
The IMA Performance Monitoring Data Menu
provides the user with present Performance
Monitoring (PM) statistics, as well as PM statistics for
the previous 6 hours. An example of the Present PM
status screen for All Links is shown in Figure 17.
The IMA Diagnostic Testing Menu provides the
ability to run both transmit and receive DRAM tests.
These tests are destructive and therefore can ONLY be
run while all IMA Facilities are unassigned.
System Management Menu
The System Management Menu allows the user to
modify non-service affecting parameters of the ATM
BCU. Parameters that may be adjusted via the System
Management Menu include the following:
Passwords
IP Address and Management PVC
Time and Date
Craft Port Baud Rate
The Password Control sub-menu allows the user to
provision three passwords, each with a different
permission level. There are three permission levels
offered, Read Only, Technician, and System
Administrator. This is explained in detail in the
Password section of this document (above).
The IP Address sub-menu allows the user to provision
the management PVC, the IP parameters for
management, and it displays the MAC Address for the
ATM BCU. These parameters must be provisioned
before the system may be remotely managed through
in-band Telnet.
The Time/Date sub-menu allows the user to set the
date and time. The date in entered in a MM/DD/YY
format and the time is entered in a 24hr clock manner.
The Baud Rate sub-menu allows the user to set the
baud rate of the craft port to 9600, 19200, or 38400
bps. The terminal or terminal emulator program must
be set at the matching baud rate to achieve
communication with the Total Access 1000 DAT.
The System Management Menu also allows the user to
upgrade the software for the ATM BCU. New
software may be uploaded using a Craft port or Telnet
connection with Y-modem protocol.
Line Interface Unit
The menus for the LIU are accessed by logging onto
the system and selecting the option corresponding to
Line Interface Unit from the Main Menu. Menus
provided by the LIU include Configuration,
Provisioning, Status, Test, Performance, and Code
Upload.
Figure 17. Present Performance Monitoring Statistics Screen for All IMA Links
Total Access 1000 (ATM) 2/06/02 13:02
Unacknowledged Alarms: None
IMA Link PM Data - Present
Link - 0 Link - 1 Link - 2 Link - 3
IMA Violations : 0 0 0 0
NE Sev. Err. Sec. : 0 0 0 0
NE Unavail. Sec. : 0 0 0 0
NE Tx Unusable Sec. : 0 0 0 0
NE Rx Unusable Sec. : 0 0 0 0
NE Tx Failures : 0 0 0 0
NE Rx Failures : 0 0 0 0
OIF Anomalies : 0 0 0 0
Tx Stuffs : 1634 1634 1633 1634
Rx Stuffs : 1634 1633 1634 1634
FE Sev. Err. Sec. : 0 0 0 0
FE Unavail. Sec. : 0 0 0 0
FE Tx Unusable Sec. : 0 0 0 0
FE Rx Unusable Sec. : 0 0 0 0
FE Tx Failures : 0 0 0 0
FE Rx Failures : 0 0 0 0
‘?’ - System Help Screen