ADTRAN 1000 Network Card User Manual


 
22 64179008APL1-5A
The Circuit Overview screen, shown in Figure 21,
provides a graphic representation of the status of each
ADSL port. The Service State Status shows the
service state of the ADSL module and each individual
port.
The ADSL Alarms Menu allows a user to view the
alarm status of each ADSL port, as well as, provision
thresholds for certain alarm conditions. Each ADSL
port has an upstream and downstream profile for
which thresholds can be set.
The ATM Loopback Menu is currently disabled.
System Alarms
The System Alarms Menu provides real-time
information concerning both acknowledged and
unacknowledged alarms for the Total Access 1000
DAT. Each alarm is displayed with a date and time
stamp, the Level of the alarm (Critical, Major, Minor,
Alert, or Info), and an Event Description. Alarms
may be cleared at any time by choosing the Clear
Alarm Log option from the System Alarms Menu.
Using this option clears both acknowledged and
unacknowledged alarms.
Configuration Prompt
The Configuration Prompt option on the Main Menu
provides access to command line driven provisioning
of the Total Access 1000 DAT. The Configuration
Prompt may be used to download provisioning scripts
so that no manual provisioning is needed. The
Configuration Prompt also allows the user to save a
configuration to another storage device for quick
restoration in the event of a loss of provisioning.
Instructions for using the Configuration Prompt are
provided upon selecting the Configuration Prompt
option from the Main Menu.
Contact Information
The Contact Information Menu provides contact
information for ADTRAN Technical Support and
Repair/CAPS, as well as, website addresses for online
support and firmware upgrades. This screen is
read-only.
Logoff Option
Only one user may provision the Total Access 1000
DAT at a time; therefore, it is important to logoff
when finished provisioning so that the system may be
accessed remotely. There is an option to set a logoff
timeout so that a user that is logged on is
automatically logged off after a certain period of non-
active time. This option may be found by accessing
the Bank Controller Unit, selecting System
Management, followed by Password Control.
Figure 21. Quad ADSL Circuit Overview Screen
Total Access 1000 (ATM)
Circuit Overview
__ __
| | ______ | |
Down: 8000 Kbps | | In Sync | | Down | | Down:
Up: 992 Kbps |1 |-------------| Quad |-------------|2 | Up:
| | | ADSL | | |
|__| | | |__|
__ | | __
| | | | | |
Down: | | Down | | | | Down:
Up: |3 |-------------| |-------------|4 | Up:
| | |______| | |