Loop loss per kft for other wire is summarized in
Table 6. Recommended maximum local loop loss
information for PIC cable at 70ºF, 135 resistive
termination is provided in Table 7.
NOTE
These approximations are to be used as guidelines
only and may vary slightly on different loops.
Adhering to the guidelines should produce
performance in excess of 10-7 BER.
6. SPECIFICATIONS
The specifications for the Total Access 1000 DAT can
be found in Table 8.
Cable Cable Temperature (ºF)
Gauge Type 68° 90° 120°
26 ................PIC ................... 3.902 ... 4.051.... 4.253
26 ................Pulp .................. 4.030 ... 4.179.... 4.381
24 ................PIC ................... 2.863 ... 2.957.... 3.083
24 ................Pulp .................. 3.159 ... 3.257.... 3.391
22 ................PIC ................... 2.198 ... 2.255.... 2.333
22 ................Pulp .................. 2.483 ... 2.545.... 2.629
19 ................PIC ................... 1.551 ... 1.587.... 1.634
19 ................Pulp .................. 1.817 ... 1.856.... 1.909
Table 6. HDSL2 Loss Values
(200 kHz cable loss in dB/kft at 135 )
Frequency (Hz) Maximum Loss (dB)
3,000 ........................................... 12.0
10,000 ........................................... 15.0
50,000 ........................................... 25.5
100,000 ........................................... 30.0
150,000 ........................................... 32.75
200,000 ........................................... 35.25
250,000 ........................................... 37.50
325,000 ........................................... 42.00
Table 7. Loop Insertion Loss Data
Table 8. Total Access 1000 DAT
Specifications
latnemnorivnE
erutarepmetgnitarepO
erutarepmetegarotS
ytidimuHevitaleR
Cº56+otCº04-
Cº58+otCº04-
,mumixamtnecrep59otpU
gnisnednocnon
lacisyhP
snoisnemiDxH.ni7.41xW.ni7.21
D.ni5.5
7. MAINTENANCE
The Total Access 1000 DAT does not require
maintenance for normal operation.
ADTRAN does not recommend that repairs be
attempted in the field. Repair services are obtained by
returning the defective unit to ADTRAN Customer
Service.