Asante Technologies 480 Switch User Manual


 
Do not tamper with the equipment. Doing so could void the warranty
Examine the work area for potential hazards (such as wet floors or ungrounded cables)
2.1.2 Recommended Installation Tools
You need the following additional tools and equipment to install the switch into an equipment rack:
Flat head screwdriver
Phillips head screwdriver
Antistatic mat or foam
2.1.3 Power Requirements
The electrical outlet should be properly grounded, located near the switch and be easily accessible. Make sure the
power source adheres to the following guidelines:
Power: Auto Switching AC, 90-240 VAC
Frequency range: 50/60 Hz
2.1.4 Environmental Requirements
Install the switch in a clean, dry, dust-free area with adequate air circulation to maintain the following environmental
limits:
Operating Temperature: 0° to 40°C (32° to 104°F)
Relative Humidity: 5% to 95% non-condensing
Avoid direct sunlight, heat sources, or areas with high levels of electromagnetic interference. Failure to observe these
limits may cause damage to the switch and void the warranty.
2.1.5 Cooling and Airflow
The IntraCore IC39240/480 switch uses internal fans for air-cooling. Do not restrict airflow by covering or obstructing
air vents on the sides of the switch.
2.2 Installing into an Equipment Rack
Important: Before continuing, disconnect all cables from the switch.
To mount the switch into an equipment rack:
15 Asante IntraCore IC39240/480 User’s Manual