Asus TS500-E4 Server Network Card User Manual


 
5-32 Chapter 5: BIOS information
Scroll down to display more items:
F1 Help
↑↓
Select Item -/+ Change Values F9 Setup Defaults
ESC Exit
→←
Select Menu Enter Select Sub-Menu F10 Save and Exit
Item Specic Help
Full fan speed will
be started when the
temperature reaches the
selected target value.
Hardware Monitor
CPU1 Throttle Temperature Margin [060]
CPU2 Throttle Temperature Margin [060]
SYSTEM1 Target Temperature [050]
SYSTEM2 Target Temperature [050]
FBD_FAN1 Speed N/A
VCORE0 Voltage 1.25 V
VCORE1 Voltage 1.25 V
VTT 1.21 V
+1.5V 1.56 V
+1.8V 1.79 V
+3V 3.28 V
+12V 11.91 V
+5V 4.87 V
+5VSB 4.96 V
VBAT 3.10 V
PhoenixBIOS Setup Utility
Advanced
CPU1/2 Domain 0/1 Temperature (CPU1/2 Throttle
Temperature Margin), SYSTEM1/2 Temperature,
C PU _ FA N 1/ 2 S p ee d, F RN _ FA N 1/ 2 /3 / 4 S pe e d,
REAR_FAN1/2 Speed
These elds show the auto-detected values and are not user-congurable.
If no fan is installed, the eld shows 0 RPM.
Smart Fan Control [Smart Fan II]
Allows you to disable or configure the Smart Fan feature. Configuration
options: [Disabled] [Smart Fan] [Smart Fan II]
CPU1/2 Domain 0/1 Target Temperature (CPU1/2 Throttle
Temperature Margin)
Allows you to set the target CPU temperature at which the CPU fan
will start running if the fan is not yet turned on. Configuration options:
[54]~[76]
SYSTEM1/2 Target Temperature
Allows you to set the target sytem temperature at which the system fan
will start running if the fan is not yet turned on. Configuration options:
[39]~[60]
FBD_FAN1 Speed, VCORE0/1 Voltage, VTT, +1.5V, +1.8V,
+3V, +12V, +5V, +5VSB, VBAT
These elds show the auto-detected values and are not user-congurable.