SN0108 / SN0116 User Manual
22
OOBC
OOBC (Out of Band Configuration), provides the ability to access the SN0108
/ SN0116 via a serial connection. This can either be a direct serial connection
from a local computer, or a dial in connection via modem.
When you click the OOBC icon, the following dialog box appears:
1. Select which port will be used for the Console Port. The Console Port is
the one that you connect the terminal or modem to for OOB
communication. The default is Port 1 (COM1), but you can use any of the
ports as long as you specify which one it is, here.
2. Specify the SN0108 / SN0116's IP address in the ServerIP field.
3. Specify the IP address of the device that will connect to the SN0108 /
SN0116 in the ClientIP field.
4. Click Update to save the information.
The various ways to access the SN0108 / SN0116 with an OOB connection, are
described in Chapter 6.