Axis Communications 540+ Printer User Manual


 
Logical Printers
98 AXIS 540+/AXIS 560
Follow the instructions below to substitute command strings:
1. From the print server’s internal Web page, select Admin | Logical
Printers.
2. Select the PR1 Web page.
3. Enter the string 01 0A 02 0D 0A in the String Substitutions text field.
4. Click the OK button.
This conversion is the default setting for logical printers PR5 through PR8.
Example:
Follow the instructions below to substitute command strings:
1. From the print server’s internal Web page, select Admin | Logical
Printers.
2. Select the PR2 tab.
3. Enter the string 01 0A 02 0D 0A 03 1B 47 31 02 1B 59 in the String
Substitutions text field.
Click the OK button.
Note:
Hex Code Explanation
01 length of the string you want to replace
0A the string you want to replace
02 length of the substitute string
0D 0A the substitute string
Assume that you want to replace the UNIX/Linux New Line (hex 0A) with an Carriage
Return/Line Feed (hex 0D 0A), and the printer command
E
C
G1 (hex 1B 47 31) with
E
C
Y (hex 1B 59) for logical printer PR2.
Hex code Explanation
01 length of the UNIX/Linux New Line command
0A the UNIX/Linux New Line command
02 length of the Carriage Return/Line Feed command
0D 0A the Carriage Return/Line Feed command
03 length of the printer command to replace
1B 47 31 the printer command to replace
02 length of the new printer command
1B 59 the new printer command
Extensive use of string substitutions will naturally decrease the throughput
rate of the Axis Network Print Server.