7. Service Mode
The following items will be displayed:
Type of projector: BarcoReality SIM6 MKII
Proj. address: To change the address of the projector, see "Projector Address", page 28
Software version
Configuration:
- front/ceiling
- front/table
- rear/ceiling
- rear/table
Baud rate PC: transfer speed for communication with an IBM PC (or compatible) or MAC. The baud rate of the projector must
be the same as the baud rate of the connected computer. When there is a difference, consult ’Change Baudrate PC’ in this
chapter.
Text: Indicates if the on screen text information (picture setting textboxes: contrast,...) is enabled or not
Projector Serial number: indicates the fabrication number of the projector. This number can be useful when calling for technical
assistance.
Projector Run Time: gives the total run time since the first start up. All projectors leave the factory with a run time of approxi-
mately 24 hours.
What can be seen on the BarcoReality SIM6 MKII Options screen ?
Following options are indicated as active or inactive (YES/NO)
Soft edge
TMR: True Motion Reproduction
•Uniformity
Motorized dimming
Rugged
Night Mode
Active 3D
7.4.2 Displaying the identification screen
Start up
1. Push the cursor key or to highlight Identification (menu 7-4)
2. Press ENTER to display the Identification screen. (menu 7-5)
3. Push the cursor key or to choose between Title page or Sim options
4. Press ENTER to confirm. (menu 7-6)
SERVICE
IDENTIFICATION
CHANGE PASSWORD
CHANGE LANGUAGE
CHANGE PROJ.ADDRESS
CHANGE BAUDRATE PC
RESET LAMP RUNTIME
LAMP RUNTIME HISTORY
DIMMING
MORE...
Select with or
then <ENTER>
<EXIT> to return
Menu 7-4
IDENTIFICATION
TITLE PAGE
SIM OPTIONS
Select with or
then <ENTER>
<EXIT> to return
Menu 7-5
BARCO
REALITY MKII SIM6
Proj. address: 001
Soft. version: 2.03
Config: FRONT/TABLE
Baudrate PC: 57600
text: ON
Serial no:1010200
Run time: 100 h
<EXIT> to return
Menu 7-6
BARCO
REALITY MKII SIM6
Soft edge: ON
TDR: ON
TMR: ON
Uniformity: ON
Mot . dimming: ON
Rugged: OFF
Night Mode: ON
Active 3D: ON
<EXIT> to return
Menu 7-7
7.5 Change password
How to enable or disable the password function ?
This item is password protected when the password strap is installed.
The password function is enabled when the password strap on the controller module is installed. Consult an authorized Barco
service technician to change the strap position.
R5976493 BARCOREALITY SIM 6 MK II 08092003