Brother DCP7010 Fax Machine User Manual


 
Confidential
9-24
M-8 Fixing unit failure
Possible cause
Step
Check
Result
Remedy
Poor
thermistor
harness
contact
1 Is the contact of connector
CN19 on the main PCB
good?
No Reconnect the connector.
Blown thermal
fuse
2 Remove the fixing unit and
measure the resistance
between the thermostat. Is
it open circuit?
Yes Replace the fixing unit.
Yes Replace the fixing unit. Thermistor
assembling
failure
3 Is the thermistor installed
properly?
No Reinstall the thermistor
properly.
Halogen
heater lamp
failure
4 Remove the fixing unit and
measure the resistance of
the halogen heater lamp. Is
it open circuit?
Yes Replace the halogen heater
lamp.
Heater harness
connection
failure
5 Is the heater harness
connector connected to the
low-voltage power supply
PCB and fixing unit
secure?
No Reconnect the connectors
securely.
NOTE:
This problem will be cleared if leaving the printer power ON for ten minutes.
M-9 Main PCB failure
Possible cause
Step
Check
Result
Remedy
Main PCB 1 Is it possible to print the
test page with the method?
No Replace the main PCB.
Software bug 2 Does this problem appear
when printing specific data
or printing under a specific
environment?
Yes Inform the Brother office of the
used specific data, printer
condition and system
environment.