WSW14
(AUTO ANS facility setting)
Selector
No.
Function Setting and Specifications
1
2
Frequency band selection (lower
limit) for incoming calling signal
(CI)
No. 1 2
0 0 : 13 Hz
0 1 : 15 Hz
1 0 : 23 Hz
1 1 : 20 Hz
3
4
Frequency band selection (upper
limit) for incoming calling signal
(CI)
No. 3 4
0 0 : 30 Hz
0 1 : 55 Hz
1 0 : 70 Hz
1 1 : 200 Hz
5
|
8
No. of rings in AUTO ANS mode
No. 5 6 7 8
0 0 0 0 : Fixed to once
0 0 0 1 : Fixed to 2 times
0 0 1 0 : Fixed to 3 times
0 0 1 1 : Fixed to 4 times
0 1 0 0 : 1 to 2 times
0 1 0 1 : 1 to 3 times
0 1 1 0 : 1 to 4 times
0 1 1 1 : 1 to 5 times
1 0 0 0 : 2 to 3 times
1 0 0 1 : 2 to 4 times
1 0 1 0 : 2 to 5 times
1 0 1 1 : 2 to 6 times
1 1 0 0 : 1 to 10 times
1 1 0 1 : 2 to 10 times
1 1 1 0 : 3 to 5 times
1 1 1 1 : 4 to 10 times
Selectors 1 through 4: Frequency band selection for incoming calling signal (CI)
These selectors are used to select the frequency band of CI for activating the AUTO ANS facility.
In the French models, if the user sets the PBX to OFF from the control panel, the setting made by
selectors 1 and 2 will take no effect and the frequency's lower limit will be fixed to 32 Hz. (Even
if the setting made by these selectors does not apply, it will be printed on the configuration list.)
Selectors 5 through 8: No. of rings in AUTO ANS mode
These selectors set the number of rings to initiate the AUTO ANS facility.