Buffalo Technology TS-RXL Computer Hardware User Manual


 
TeraStation User Manual 148
Error and Warning
Displays the current status when changing the settings or formatting drives.
Examples of LCD Meaning
SYSTEM Error E00
MPU No Response
System is not responding. Unplug the power code of the TeraStation and reboot it. If the
error still persists, contact BUFFALO’s service center for repair.
DRAM LINES E01
DATA Failure
Some parts of internal IC is not working properly. Contact BUFFALO’s service center for
repair.
DRAM LINES E02
ADDRESS Failure
Some parts of internal IC is not working properly. Contact BUFFALO’s service center for
repair.
RTC Chip E03
No RTC Clock
Some parts of internal IC is not working properly. Unplug the power code of the TeraStation
and reboot it. The error still persists, contact BUFFALO’s service center for repair.
SYSTEM Error E04
Can’t Load Krnl!
The rmware is corrupted. Contact BUFFALO’s service center for repair.
WDT E05
SYSTEM Stopped
System hung up. Unplug the power code of the TeraStation and reboot it. If the error still
persists, contact BUFFALO’s service center for repair.
TFTP MODE E06
Lost boot image
The rmware is corrupted.
Contact BUFFALO’s service center for repair. Wait for 5 minutes to show “E04” and turn o,
or press and hold the power button for 10 seconds.
HD ALL E07
ALL HD Not Found
Hard disks are not found.
Even if the hard disks are connected but this message is displayed, contact BUFFALO’s
service center for repair.
UPS E10
Dependent Mode
Operating using UPS battery due to the power outage. System will be shut down safely.
Check the power supplied to UPS, and turn TeraStation o if there is no problem on UPS.
SYSTEM I10
TOO HOT!
Temperature in the system may be over the limits of warranty. Do not place any object
around the TeraStation. Or move the TeraStation to the cooler place.
SYSTEM Error E11
Fan Failure
There is a problem with the number of fan spinning.
Check if there is any objects or dusts on the fan. If you see any objects or dusts, remove them
by tweezers or an air duster. The error still persists, contact BUFFALO’s service center for
repair.
SYSTEM Error E12
Cooling Failure
Temperature in the system is over the limits of warranty. Do not place any object around the
TeraStation. Or move the TeraStation to the cooler place.
RAID Error E13
ARRAYx Error
An error occurs in Xth RAID array. When rebooting the TeraStation, it will run as degrade
mode when RAID 1 or RAID 5 is used. You can use an erroneous drive by rebuilding, but it is
recommended that you replace the erroneous drive immediately.
RAID Arrayx E14
Can’t Mount
Xth RAID array could not be mount. Turn o TeraStation, and turn it on again. If the error still
persists, rebuild RAID. If the error still persists, contact BUFFALO’s service center for repair.
HDx Error E15
Many Bad Sectors
The bad sector in xth hard drive has reached the dangerous zone. Replace Xth hard drive.
HDx Error E16
HDx Not Found
Cannot nd the Xth hard drive.The Xth hard drive may not connected or may be damaged.
Replace the hard drive.