Cabletron Systems 2H33-37R Switch User Manual


 
Chapter 5: Local Management
5-30 2H23-50R/2H33-37R User’s Guide
5.7.10.1 Changing the COM Port Application
After enabling the COM port as described in Section 5.7.10, one of the
applications supported by the COM port (LM or UPS) can be selected.
The default application is LM.
To change the COM port application:
1. Use the arrow keys to highlight the Application field.
2. Use the SPACE bar or BACKSPACE to step through the available
settings until the operation you require displays. Table 5-3 lists the
available settings and their corresponding applications.
3. Press ENTER to accept the application.
4. Use the arrow keys to highlight the SAVE command at the bottom of
the screen, then press the ENTER key. The message “SAVED OK”
displays, indicating that the edits are saved.
5.7.11 Clearing NVRAM
Clearing NVRAM allows the user to clear all user-entered parameters,
such as the IP address and Community Names from NVRAM.
Table 5-3 COM Port Application Settings
Setting Application
LM Local Management Session
UPS APC Power Supply SNMP Proxy
!
CAUTION
When the COM port is configured to perform the UPS
application, all future Local Management connections must be
made by establishing a Telnet connection to the device. Ensure
that the device has a valid IP address before saving changes to
the COM port application. If the device does not have a valid IP
address and the changes are saved, refer to Appendix C for
instructions on clearing NVRAM in order to reestablish COM
port communications.
!
CAUTION
Clearing NVRAM results in the loss of all user-entered
parameters. Do not proceed unless the following procedure is
completely understood.