Cabletron Systems 42T Switch User Manual


 
INSTALLATION
3-2
Figure 3-1. Attaching the Strain Relief Bracket
3.3 INSTALLING THE MicroMMAC-T
The MicroMMAC-T can be rack-mounted, wall-mounted, or placed on
any horizontal surface. Refer to the following subsections for the
appropriate installation instructions. When installing the MicroMMAC-T
into something other than a 19-inch rack, installation requires the
following:
An unrestricted free surface area at least 21 inches wide, 18 inches
deep, and 6 inches high.
A single phase 85 to 264 Vac, 15A, grounded power receptacle located
within 7 feet of the site.
If a shelving unit is used, it must be able to support 30 pounds of static
weight.
The temperature in selected location must be between 5° and 50°C,
and change less than 10°C per hour.
NOTE: Be sure that the selected location is within reach of the network
cabling.
3.3.1 Rack-Mounting the MicroMMAC-T
Refer to Figure 3-2 and perform the following steps to install the
MicroMMAC-T in a 19-inch rack:
1. Remove the four cover screws located along the front edges of each
side of the MicroMMAC-T.
TOKEN RING HUB
WITH
LANVIEW®
SUPPORTING 100 OHM STP CABLE
MicroMMAC-24T