142 Appendix D: Using telnet
297-8991-910 Standard 03.01 August 1999
Telnet access to a switch
Procedure 12 Telnetting into a switch for MAP session access (pre-CSP05)
Step Action
1 Go to the CI level of the MAP display.
2 Open table IPHOST by typing
>table IPHOST
and pressing the Enter key.
3 List available EIUs by typing
>list all
and pressing the Enter key.
4 Locate the EIU in the list and determine
a. the EIU IP address on the SuperNode side
b. that there are enough available connections on the CM and the EIU
5 Close table IPHOST by typing
>quit
and pressing the Enter key.
6 Open table RMCONFIG by typing
>table RMCONFIG
and pressing the Enter key.
7 Determine that there are enough MAP and telnet sessions.
8 Close table RMCONFIG by typing
>quit
and pressing the Enter key.
9 Open an xterm window.
10 Telnet into the EIU by typing
>telnet ip_addr
and pressing the Enter key.
where
ip_addr is IP address that you found at step 4
11 You have completed this procedure.
CAUTION
Possible loss of service
To avoid reliability problems, establish telnet sessions on the
DMS switch only with CSP05 software and above. If you
encounter problems, contact your next level of support.