Cisco Systems 9266CV-8i Server User Manual


 
3-12
Cisco UCS C220 Server Installation and Service Guide
OL-25760-01
Chapter 3 Maintaining the Server
Installing or Replacing Server Components
Replacing Hard Drives or Solid State Drives
This section includes the following information:
Drive Population Guidelines, page 3-12
Drive Replacement Procedure, page 3-13
Drive Population Guidelines
The server has two different drive backplane options:
The Small Form Factor drives version can hold up to eight 2.5-inch hard drives or solid state drives.
The Large Form Factor drives version can hold up to four 3.5-inch hard drives.
The drive-bay numbering is shown in Figure 3-6.
Figure 3-6 Drive Numbering, Small Form Factor
Figure 3-7 Drive Numbering, Large Form Factor
Observe these drive population guidelines for optimum performance:
When populating drives, add drives to the lowest-numbered bays first.
Keep an empty drive blanking tray in any unused bays to ensure proper air flow.
You can mix hard drives and SSDs in the same server (the LFF version of the server does not support
SSDs). However, You cannot configure a logical volume (virtual drive) that contains a mix of hard
drives and SSDs. That is, when you create a logical volume, it must contain all hard drives or all
SSDs.
HDD4 HDD5
HDD1
HDD6
HDD2
HDD7
HDD3
HDD8
331695
HDD1 HDD2 HDD3 HDD4
331696