Cisco Systems IPMUX-1 Network Router User Manual


 
IPmux-1/1E Installation and Operation Manual Appendix E Configuration Menus
IPmux-1 E1/T1 Configuration E-19
Table E-12. E1 Physical Layer Configuration Parameters (Cont.)
Parameter Possible Values Remarks
Uplink Fail Alarm
Behavior
Cond
AIS
Selects notification by the agent TDM side if Ethernet link fails
IPmux-1/1E sends a Cond. Error that was configured by the
user
IPmux-1/1E transmits unframed AIS on the E1 channel that
was connected to the LAN
Signaling mode
CAS enable
CAS disable
The E1 framer is set to CAS MF mode and the operation mode
to fractional with CAS mode.
CAS MF will not be set in the E1 framer and the operation
mode will be configured to fractional mode.
Note: This field will not appear if “unframed” is selected in the
Line Type field.
Default: CAS Enable
Cond. Data Pattern 00 to FF Conditioning pattern can be applied to timeslots toward the IP
path when loss of signal, loss of frame or AIS is detected at the
E1 line. Conditioning pattern can also be applied to timeslots
toward the E1 line when packet receive buffer overrun or
under-run occurs. In Unframed mode, conditioning state will
result in AIS transmission. This will be applied when a LOS is
detected at E1 line, or when packet receive buffer overrun or
under run occurs.
Note: This field will not appear if “unframed” is selected in the
Channel Type field.
Default: FF
Cond. CAS (ABCD)
Pattern
1 to F The ABCD conditioning pattern can be applied toward the IP
path when loss of signal, loss of frame, or AIS is detected at the
E1 line. Conditioning pattern can also be applied toward the
E1 line when packet receive buffer overrun or underrun occur.
Note: This field will not appear if “Unframed” is selected in the
Channel Type field.
Default: 1