Cisco Systems OL-7822-06 Computer Drive User Manual


 
4-12
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 4 Connect the Management Interfaces and Perform Initial System Configuration
Perform the Initial System Configuration
Would you like to enter the DNS configuration menu? [no]: y
Enable IP DNS-based hostname translation? [yes]:
Enter default domain name []: pcube.com
Enter Primary DNS IP address: 10.1.1.230
Would you like to add another Name Server? [no]:
Step 6: Configuring the RDR Formatter Destination
The SCE 1000 passes Raw Data Records (RDRs) to an external collection system via the
RDR-Formatter. In order for the data to reach the correct location, the IP address of the external
collection system and its port number must be configured.
Step 1 Enter the RDR formatter configuration menu.
Would you like to enter the RDR-formatter configuration menu? [no]: y
Type y and press press Enter.
The RDR-formatter destination dialog begins.
Step 2 Specify the IP address of the RDR-formatter destination.
Type the IP address of the RDR-formatter destination and press press Enter.
Enter RDR-formatter destination’s IP address:
Note that there is no default for this parameter.
Step 3 Specify the TCP port number of the RDR-formatter destination.
Type the TCP port number of the RDR-formatter destination and press press Enter.
Note that there is no default for this parameter.
Enter RDR-formatter destination’s TCP port number:
EXAMPLE:
Following is a sample RDR-formatter configuration dialog, assigning the IP address and TCP port
number.
Would you like to enter the RDR-formatter configuration menu? [no]: y
Enter RDR-formatter destination’s IP address: 10.1.1.230
Enter RDR-formatter destination’s TCP port number: 33000
Step 7: Configuring Access Control Lists (ACLs)
Information About Access Control Lists, page 4-12
Examples, page 4-15
Information About Access Control Lists
Configuring ACLs, page 4-13
Entry Formats, page 4-13
Order of Entries, page 4-13