Cisco Systems OL-7822-06 Computer Drive User Manual


 
8-2
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 8 Troubleshoot Startup Problems
SCE 1000 Operational Status
Warning SCE 1000 is fully operational (as
above) but one of the following
occurred:
Line ports (GBE ports) to
the link are down
Management port link is
down
Temperature raised above
threshold
Voltage not in required
range
Fans problem
Power supply problem
Insufficient space on the
disk
Note If the condition that
caused the SCE 1000 to
be in Warning state is
resolved (for example,
link is up) the SCE 1000
reverts to Operational
state.
Flashing orange
Failure System is in Failure state after
Boot due to one of the following
conditions:
Power on test failure
Three abnormal reboots in
less than 20 minutes
Platform configured to enter
Failure mode consequent to
failure-induced reboot (this
is configurable using CLI
command)
Note Depending on the cause
of failure, the
management interface
and the platform
configuration may or
may not be
active/available.
Red
Table 8-1 SCE 1000 Operational States (continued)
SCE 1000 Operational Status Description Status LED State