Citizen CL-S700R Label Maker User Manual


 
Chapter 3 Disassembly and Maintenance
3-6. Adjustments
CL-S700/CL-S703/CL-S700R 3-54
3-6-4. Ribbon Tension Adjustment
Perform the ribbon tension adjustment when the “Unit, Frame Ribbon L” is replaced with new one.
Preparation:
Make a “Ribbon-tension adjust ribbon” and “Ribbon-tension spring adjust ribbon” to be used in the
adjustment procedure.
Diameter of ribbons should be 60mm and 80mm, respectively.
Reinforce the ribbon end with paper or the like and punch a hole in the center as shown in the
figure.
As shown in the figure, stick a tape inside the “Ribbon-tension spring adjust ribbon (φ80mm)” at
about 150mm from the edge. (This tape acts to prevent the weight hooked on the ribbon hole from
falling to the floor. Without the tape, you cannot perform adjustment properly.)
[Ribbon-tension adjust ribbon] [Ribbon-tension spring adjust ribbon]
φ60mm
φ80mm
150mm
Tape