5. Remove the “SA, Open Guide U” [8-11].
1) Pull out “Knob, Sensor Adjust” [8-20], disengage 1 E-ring (E-Ring, 3) [8-26], and
remove the “Bushing 3, Adjust Sensor” [8-18] and “Spring, Guide Sensor Up” [8-17]
from the “Shaft, Sensor Adjust” [8-16].
2) Disengage 1 E-ring (E-Ring, 2) [8-28], pull out “Pin, Teeth Spring 1.2x8” [8-3], remove
the Screw Gear [8-4] and “Shaft, Sensor Adjust” [8-16], and detach the “SA, Open
Guide U” [8-11] from the “SA, Open Guide L” [8-22].
Note on reassembling:
Apply grease (Floil G-311S) to the following points (refer to the places marked with in
Drawing No. 8 “Unit, Sensor Adjust” for the Printer Part in Chapter 5 “Parts List”):
“Bushing 3, Adjust Sensor” [8-18]: Rear surface (where contacting with E-ring)
“SA, Open Guide U” [8-11]: 2 holes for the “Shaft, Sensor Adjust” [8-16]
“SA, Open Guide L” [8-22]: 2 holes for the “Shaft, Sensor Adjust” [8-16]
6. Remove the “SA, Open Guide L” [8-22].
1) Remove 2 screws (PH (SW+PW), M3x5) [8-29] and detach the “Holder, Sensor L”
[8-25].
2) Peel off the “Sheet, Sensor Adjust” [8-15] and “Sheet, Sensor Adjust L” [8-32], and
remove the “Cover, RFID” [8-21] from the “SA, Open Guide L” [8-22].
Note on reassembling:
Apply grease (Floil G-311S) to the following points (refer to the places marked with in
Drawing No. 8 “Unit, Sensor Adjust” for the Printer Part in Chapter 5 “Parts List”):
“SA, Open Guide L” [8-22]: 2 holes for the “Shaft, Sensor Adjust” [8-16]