fn = 5: Function 5 Setting Customized Value
GS (E pL pH fn [a1 n1L n1H]...[ak nkL nkH] fn = 5
[Code] <1d>H<28>H<45>pL pH fn [a1 n1L n1H]...[ak nkL nkH]
[Range] 4 (pL + pH × 256) 65535
fn = 5
1 a 3 a = 5, 6, 97, 116, 201, 202
1 (nL + nH × 256) 65535
[Default] Described in the processing table for “a”.
[Outline] Sets the customized value set in “a” to (nL + nH × 256).
a Function
3 Selects paper width.
5 Selects printing density.
6 Selects printing speed.
97 Selects the number of divisions for conducting head.
116 Selects printing color.
201 Sets ACK output position (only parallel I/F).
202 Selects input buffer full Busy output/cancel timing (idle capacity).
a = 3: Sets paper width to the size specified by (nL + nH × 256).
(nL + nH × 256) Paper Width
2 58 mm
3* 60 mm
6 (Default) 80 mm
* No function with CT-S300.
a = 5: Sets printing density to the level specified by (nL + nH × 256).
(nL + nH × 256) Printing Density
65530 0.7 times
65531 0.75 times
65532 0.8 times
65533 0.85 times
65534 0.9 times
65535 0.95 times
0 (Default) 1
1 1.05 times
2 1.1 times
3 1.25 times
4 1.2 times
5 1.25 times
6 1.3 times
7 1.35 times
8 1.40 times