Citizen CT-S300 Printer User Manual


 
— 110 —
fn = 49: Function 49 Setting Printing Density
GS (K pL pH fn m fn = 49
[Code] <1d>H<28>H<4B>pL pH fn m
[Range] (pL + pH × 256) = 2 : (pL = 2, pH = 0)
fn = 49
0 m 9, 250 m 255
[Default] m = 0 (Customized value setting value)
[Outline] Sets printing density.
m Printing Density
250 Selects density level –6 (70%)
251 Selects density level –5 (75%)
252 Selects density level –4 (80%)
253 Selects density level –3 (85%)
254 Selects density level –2 (90%)
255 Selects density level –1 (95%)
0 Selects standard density (100%)
1 Selects density level + 1 (105%)
2 Selects density level + 2 (110%)
3 Selects density level + 3 (115%)
4 Selects density level + 4 (120%)
5 Selects density level + 5 (125%)
6 Selects density level + 6 (130%)
7 Selects density level + 7 (135%)
8 Selects density level + 8 (140%)