fn = 97: Function 97 Setting Number of Divisions for Head
Conducting
GS (K pL pH fn m fn = 97
[Code] <1d>H<28>H<4B>pL pH fn m
[Range] (pL + pH × 256) = 2 : (pL = 2, pH = 0)
fn = 97
0 m 6, 48 m 52
[Default] m = 9 (Customize value setting)
[Outline] Sets the number of divisions for head conducting.
m No. of Divisions for Head Conducting
0, 48 No. of divisions at power on.
2, 50 Selects 2-division conducting.
4, 52 Selects 4-division conducting.