Citizen CT-S300 Printer User Manual


 
— 83 —
GS C1 n1 n2 n3 n4 n5 n6
[Function] Setting the numbering counter mode (A)
[Code] <1D>H<43>H<31>H<n1><n2><n3><n4><n5><n6>
[Range] 0 n1 , n2 , n3 , n4 , n5 , n6 255
[Outline] This command sets the numbering (serial number counter) mode.
n1 + n2 × 256 (n1 = remainder, n2 = quotient): Counter default
n3 + n4 × 256 (n3 = remainder, n4 = quotient): Counter final value
n5: Counter step value
n6: Idential counter print counter
(n1 + n2 × 256) < (n3 + n4 × 256): Count-up system
(n1 + n2 × 256) > (n3 + n4 × 256): Count-down system
(n1 + n2 × 256) = (n3 + n4 × 256) or n5 = 0 or n6 = 0: Counter stop
[Default] n1 + n2 × 256 = 1
n3 + n4 × 256 = 65535
n5 = 1
n6 = 1
[See Also] GS C0 , GS C2 , GS c , GS C ;
[Sample Program]
LPRINT CHR$(&H1D);"C0"; *CNT
LPRINT CHR$(3);CHR$(0); FOR I=1 TO 5
LPRINT CHR$(&H1D);"C1"; LPRINT CHR$(&H1D);"c";
LPRINT CHR$(50);CHR$(0); NEXT I
LPRINT CHR$(0);CHR$(0); LPRINT CHR$(&HA);
LPRINT CHR$(5);CHR$(2); RETURN
GOUSAB *CNT
LPRINT CHR$(&H1D);"C2";
LPRINT CHR$(5);CHR$(0);CHR$(10);
GOUSAB *CNT
END
[Print Results]
When printing the counter value by setting a count-down
range = 0 to 50, step value = 5, repeat count = 2, and
starting value = 50.
When printing the counter value by setting a count-down
range to 0 to 50, step value = 5, repeat count = 1, and
starting value = 5, step cleared.
50 50 45 45 40 <
5 0 50 45 40 <