Citizen CT-S300 Printer User Manual


 
— 106 —
fn = 11: Function 11 Setting Communication Conditions of Serial
Interface
GS (E pL pH fn a d1...cdk fn = 11
[Code] <1d>H<28>H<45>pL pH fn a d1..dk
[Range] 3 (pL + pH × 256) 65535 (0 pL 255, 0 pH 255)
fn = 11
1 a 4 (Not changed in other than specified range)
48 d 57 (Not changed in other than specified range)
1 k 6
[Outline] Sets the communication conditions of serial interface specified by “a”.
a = 1: Setting baud rate
Baud Rate d1 d2 d3 d4 d5 d6
2400 50 (“2”) 52 (“4”) 48 (“0”) 48 (“0”)
4800 52 (“4”) 56 (“8”) 48 (“0”) 48 (“0”)
9600 57 (“9”) 54 (“6”) 48 (“0”) 48 (“0”)
19200
49 (“1”) 57 (“9”) 50 (“2”) 48 (“0”) 48 (“0”)
(Default)
38400 51 (“3”) 56 (“8”) 52 (“4”) 48 (“0”) 48 (“0”)
Operates only in printer function setting mode.
Which of dip SW or memory SW is used at initialization depends on “Selecting
communication condition setting” of dip SW1-1.
a = 2: Setting to specified parity
d1 Parity Setting
48 (Default) No parity
49 Odd parity
50 Even parity
d1 Flow Control
48 (Default) DSR/DTR
49 XON/XOFF
a = 3: Setting to specified flow control
d1 Setting Data Length
55 7-bit length
56 (Default) 8-bit length
a = 4: Setting to specified data length