Citizen CT-S300 Printer User Manual


 
— 115 —
fn = 3, 51: Function 3
GS (M pL pH fn m fn = 3, 51
[Code] <1d>H<28>H<4D>pL pH fn m
[Range] (pL + pH × 256) = 2 : (pL = 2, pH = 0)
fn = 3, 51
m = 0, 1, 48, 49
[Outline] Determines the setting of storage area at initialization to the work area by the value
of “m”.
m Function
0, 48 Does not copy data from storage area to work area at initialization.
1, 49 Copies data from storage area to work area at initialization.