Cognitive Solutions A776 All in One Printer User Manual


 
Chapter 3: Migrating to a new printer
A776-PG00001 C 12/09 A776 (B780) Programming Guide
9
Moving from the A756, A758, or A760 to the A776 (Slip dierences)
The impact station print zone on the A760 is 4.7 inches wide and the print zone on the A776 is 3.0 inches. To compensate for
the narrower print zone on the A776 the rmware will provide the following functionality:
1. For applications that currently use narrow forms with 42 or fewer columns, an option is provided to delete x leading
spaces. No application or form changes should be required.
2. For applications that use narrow forms with 51 or fewer columns, an option is provided to default to compressed
mode. No application or form changes should be required.
3. For applications using wide forms that print on less than 51 columns, options 1 and 2 above are combined with the
option to delete trailing spaces. There should be no changes required to the application but a new form will be
required.
4. For applications using wide forms that print on more than 51 columns, the data will wrap to the next line. If you
don’t want data to wrap you will need to change the application and the form.
A756, A758, A760 A776
Impact Station Print Zone 4.7 inches 3 inches
Characters/row – Normal Mode 66 42
Characters/row – Compressed Mode 80 51
See Chapter 4: Programming the Printer for more details about the slip print zones.
Some commands have new functions for the slip and can be congured to be enabled or disabled on the slip. Existing
applications that use these functions on the receipt but not on the slip may need to be disabled manually for the slip. The
default is disabled for the slip.
• 1B 21 10 double high slip character print
• 1B 20 n slip character right side spacing
• 1D 50 XY set minimum units for the slip station
• 1D 4C nL nH set left margin on the slip station
• 1D 57 nL nH set print width on the slip station
• 1B 61 n print justication on the slip station
Moving from the A756 to the A776 (Emulation commands)
These commands are handled dierently when the A776 is in A756 emulation mode.
1B 47 enable double strike (the dierence is no parameter byte req’d)
1B 48 disable double strike
1B 4C... double density graphics command sequence