Compaq 9900 Network Card User Manual


 
72 Chapter 4
Configuring and Using the 9900 Subsystem
Table 4.6 ICKDSF Commands for 9900 Contrasted to RAMAC
Command Argument Subsystem Return Code
INSPECT KEEPIT RAMAC CC = 12 Invalid parameter(s) for device type.
9900 CC = 12, F/M = 04 (EC=66BB).
PRESERVE RAMAC CC = 4 Parameter ignored for device type.
9900 CC = 12, F/M = 04 (EC=66BB) Unable to establish primary and
alternate track association for track CCHH=xxxx.
SKIP RAMAC CC = 4 Parameter ignored for device type - skip.
9900 CC = 12, F/M = 04 (EC=66BB) Primary track
CCHH-xxxx found unrecoverable.
NOPRESERVE,
NOSKIP,
RAMAC CC = 0, ALT information not displayed.
NOCHECK 9900 CC = 0
ALLTRACKS,
ASSIGN,
RECLAIM
RAMAC CC = 12 Invalid parameter(s) for device type.
9900 In case of PRESERVE: CC = 12,
In case of NO PRESERVE: CC = 0.
INSTALL SETMODE (3390) RAMAC CC = 0 (but not recommended by IBM).
9900 CC = 0
SETMODE (3380) RAMAC CC = 12, Invalid parameter(s) for device type.
9900 CC = 12, Function not supported for nonsynchronous DASD.
ANALYZE RAMAC CC = 0
9900 CC = 0
BUILDX RAMAC CC = 0
9900 CC = 0
REVAL REFRESH RAMAC CC = 12 Device not supported for the specified function.
9900 CC = 12, F/M = 04 (EC=66BB) Error, not a data check.
Processing terminated.
DATA,
NODATA
RAMAC CC = 0, Data/Nodata parameter not allowed.
9900 CC=0
CONTROL RAMAC CC = 0, ALT information not displayed.
9900 CC = 0, ALT information not displayed.
INIT RAMAC CC = 0, ALT information not displayed.
9900 CC = 0
REFORMAT RAMAC CC = 0, ALT information not displayed.
9900 CC=0
CPVOLUME RAMAC CC = 0, Readcheck parameter not allowed.
9900 CC=0
AIXVOL RAMAC Readcheck parameter not allowed.
9900 CC = 0