A: BladeManager Hardware Specifications
A-2 AlterPath BladeManager Manual
Expansion Slots Two 66 MHz/64-bit PCI-X slots (one low profile
half-length, one full-height three-quarter-length)
Video Controller ATI Radeon 7000M IGP video on system board
Compatible with SVGA and VGA
16 MB DD-SDRAM video memory
Power 300 watt (110 or 220 V ac auto sensing)
Operating Environment
Air Temperature Server on: 10
o
to 35
o
C (50
o
to 95
o
F)
Altitude: 0 to 914 m (2998.7 ft)
Server off: -40
o
to 60
o
C (-104
o
to 140
o
F)
Maximum altitude: 2133 m (6998 ft)
Humidity Server on: 8% to 80%
Server off: 8% to 80%
Heat Output Approximate heat output in British thermal units
(Btu) per hour:
Minimum configuration: 307 Btu (90 watts)
Maximum configuration: 850 Btu (250 watts)
Acoustical noise emissions Sound power, idling: 6.5 bel maximum
Sound power, operating: 6.5 bel maximum
Certifications FCC Class A, CE
Notes:
Power consumption and heat output vary depending on the number and type
of optional features installed and the power-management optional features in
use.
These levels were measured in controlled acoustical environments according
to the procedures specified by the American National Standards Institute
(ANSI) S12.10 and ISO 7779 and are reported in accordance with ISO 9296.
Actual sound-pressure levels in a given location might exceed the average
values stated because of room reflections and other nearby noise sources. The
declared sound-power levels indicate an upper limit, below which a large
number of computers will operate.