Datalogic Scanning DS8100A Scanner User Manual


 
DS8100A
2
2.3.3 Ethernet Connector
This connector is only available for DS8100A Ethernet models and allows the Ethernet
connection between the host and the reader.
Figure 29 – Harting RJ Industrial® Push Pull Male Connector
1
8
Figure 30 – DS8100A Harting RJ Industrial® Female Connector
This interface and the connector pinout (see the following table) are IEEE 802.3 10 BaseT
and IEEE 802.3u 100 Base Tx compliant.
ModulRJ45 ar Jack Pinout
P in Name Function
1 TX + Transmitted data (+)
2 TX - Transmitted data (-)
3 RX + Received data (+)
6 RX - Received data (-)
4, 5, 7, 8 N.C. Not connected
rder to meet EMC requirements: In o
use th shie
c t the E
E lded cable
thernet interface cable shield to the plant earth ground onnec
NOTE
A ferrite (type Stewart 28A2029-0A0) must be applied on the scanner side
of the Ethernet cable to reduce electrical noise. The cable shield must
also be connected to the chassis of both connectors.
22