5 MAINTENANCE
5.1 CLEANING
lean the laser beam output window periodically for correct operation of the scanner (see
igure A and Figure B in chapter "General View").
Dust, dirt, etc. on the window may alter the reading performance.
Rep
se avoid any abrasive substances.
C
F
eat the operation frequently in particularly dirty environments.
U
soft material and alcohol to clean the window and
W
is turned off or at
am is not active.
Clean the window of the DS8100A when the scanner
least when the laser be
ARNING
.2 AUTOMATIC SCANNER REPLACEMENT (ASR)
The Da logic A
functioning automatically after one or more scanners are replaced in a Master/Slave
he ASR procedure is principally used for PackTrack™ configurations, since it restores the
PackTrack™ calibration from the slave scanner to be substituted to the new scanner.
The Master must be prepared at the time of installation in order for this procedure to work
correctly.
5.2.1 ASR Network Configuration
1. On the Master scanner, check the Modify & Backup Lon Slave Scanner
Configuration parameter in Genius™ and configure the Lonworks Slave Scanner
Common Parameters (Code and Reconstruction Parameters).
2. Enable the ASR procedure through the Enable A.S.R. parameter in the Master
configuration.
3. Send the configuration to the Master EEPROM to force the Slave Operating Mode, Code
Reading Symbologies, Reconstruction parameters and store all the Slave PackTrack™
calibration tables.
Now the Slave scanners are configured through the Master and the ASR procedure is
implemented.
4. Save this configuration to file (.ddc).
5
ta utomatic Scanner Replacement (ASR) procedure allows restoring system
Lonworks network.
T
70