Datalogic Scanning DS8100A Scanner User Manual


 
READING FEATURES
4
Minimum Code Height for ACR Reading (mm)
45° 30°
Conveyor Speed (m/s) 0.5 1 1.5 2 2.5 3 0.5 1 1.5 2 2.5 3
0.25
9 9 11 12 14 15 6 7 8 9 10 11
0.30
10 11 12 13 15 16 7 7 8 10 11 12
0.33
11 11 12 14 15 17 7 8 9 10 11 12
0.38
12 13 13 15 16 18 8 8 9 10 12 13
0.50
15 16 16 17 18 20 9 10 11 12 13 14
0.72
20 21 22 22 23 24 13 13 14 14 15 16
Code 39
Code Resolution
(mm)
1.00
27 28 29 29 30 31 17 17 18 18 19 20
Ratio 3:1; Interdigit = Module Size
Table 2
Minimum Code Height for ACR Reading (mm)
45° 30°
Conveyor Speed (m/s) 0.5 1 1.5 2 2.5 3 0.5 1 1.5 2 2.5 3
0.25
7 9 10 12 13 15 6 6 8 9 10 11
0.30
8 9 11 12 14 15 6 7 8 9 10 12
0.33
9 10 11 13 14 16 6 7 8 9 11 12
0.38
10 11 12 14 15 17 6 8 9 10 11 12
0.50
12 13 14 16 17 19 8 9 10 11 12 13
0.72
16 17 18 19 21 22 10 11 12 13 14 15
Code 128 – Ean 128
Code Resolution
(mm)
1.00
21 22 23 24 25 26 13 14 15 16 17 18
Table 3
Minimum Code Height for ACR Reading (mm)
45° 30°
Conveyor Speed (m/s) 0.5 1 1.5 2 2.5 3 0.5 1 1.5 2 2.5 3
0.25
8 9 10 12 13 15 5 6 8 9 10 11
0.30
9 9 11 12 14 15 6 7 8 9 10 12
0.33
9 10 11 13 14 16 6 7 8 9 11 12
0.38
10 11 12 14 15 17 7 8 9 10 11 12
0.50
13 13 14 16 17 19 8 9 10 11 12 13
0.72
17 18 18 19 21 22 11 11 12 13 14 15
Codabar
Code Resolution
(mm)
1.00
23 23 24 25 26 26 14 15 15 16 17 18
Ratio 3:1; Interdigit = Module Size
Table 4
Minimum Code Height for ACR Reading (mm)
45° 30°
C (m/s) 0.5 1 1.5 2 2.5 3 0.5 1 1.5 2 2.5 3 onveyor Speed
0.25
7 8 9 11 12 14 5 6 7 8 9 11
0.30
8 9 10 11 13 14 6 6 7 9 10 11
0.33
9 10 10 12 13 15 6 7 8 9 10 11
0.38
10 11 11 12 14 15 6 7 8 9 10 12
0.50
12 13 14 14 15 17 8 8 9 10 11 12
0.72
16 17 18 18 19 20 10 11 11 12 13 14
E -
C
21 22 23 24 24 25 13 14 15 15 16 16
AN 8-13, UPC A
ode Resolution
(mm)
1.00
Table 5
59