INSTALLATION
2
PLC Host
P.S.*
P.S.*
Gryphon
Fieldbus
Network
DS4600
A
DS4600
A
DS8100
A
CAB601X
C-BOX 100
C-BOX 100
AUX
C-BOX 100
P.S.*
1 2 1 2
PWR-120
1
2
Main Serial Interface
A
uxiliary Serial Interface
* P.S. (Presence Sensor) connected to External Trigger/PS input.
Figure 40 – Pass Through Connection for Fieldbus Models
2.6.3 RS232
The RS232 master/slave connection is used to integrate a DS8100A reader in a network
consisting of diff
The Sla e scan
scanner transmi .
All m es wi
master scanner is connected to the Host PC on the main RS232 serial interface through
the C-BOX 100 (20 mA C.L. can also be used if the INT-30 accessory is installed).
In RS232 Master/Slave connections the External Trigger signal is unique to the system
(single P.S.).
Master/Slave
erent scanners not provided with a Lonworks interface.
ners use RS232 only on the main and auxiliary interfaces. Each slave
ts the messages received by the auxiliary interface onto the main interface
ll be transferred towards the master.
v
essag
The
NOTE
The DS8100A Standard model, working as Master in an RS232 network,
may be simultaneously
connected to a Lonworks network consisting of
DS8100A slave scanners. Be careful when assigning the slave address,
since the number of the first Lonworks slave must be a progressive
number with respect to the address number defined for the last slave
scanner of the RS232 network. For example, if the RS232 network
consists of Slave 1 and Slave 2, the address to be assigned to the first
Lonworks slave scanner will be Slave 3 (not Slave 1).
29