Datalogic Scanning DS8100A Scanner User Manual


 
DS8100A
3
3. Then, proceed with the network setup
by using one of the icons available on the Tool
Bar according to the procedure to follow:
=
Net-Autoset procedure
= Network Wizard procedure
=
Express Network Setup procedure
Net-Autoset
This procedure is to be used when all scanner addresses and labels are unknown (typically
when configuring the network for the first time or whenever a network reconfiguration is
required).
By clicking the
icon or selecting the "Net_Autoset" option from the right-click menu, the
Net-Autoset procedure is started allowing automatic assignment of random addresses to all
slave or Stand Alone scanners connected within the network.
Once the procedure has been completed, it is possible to:
define customized addresses and labels through the Network Wizard;
display the scanner default labels through the Express Network Setup.
xpress Network Setup
Before
scanne
E
performing this procedure, a Lonworks address must be assigned to each slave
r. The most practical method is through the
Net-Autoset procedure. See par. 3.2.3 for
tive address assignment methods.
ll addresses have been assigned, the Express Network Setup is to be used when all
r addresses and labels do not need to be modified
alterna
Once a
scanne
.
By clicking on the
icon or by choosing the related option from the right-click menu, the
procedure is started which automatically performs the following operations:
- opening the wizard;
- polling the network to discover connected scanners;
- transferring all scanners found to the "Requested Devices" area of the wizard where
your network customization is defined;
Once t
the con
- saving the new network configuration;
he procedure has been completed, a dialog box will appear asking whether to send
figuration to the Master. Choose the “Yes” option to start this procedure.
46