Dell 53-1002116-01 Network Card User Manual


 
4 Dell Converged Enhanced Ethernet Administrator’s Guide
53-1002116-01
Layer 2 Ethernet overview
1
The Dell FCoE hardware handles Ethernet frames as follows:
When the destination MAC address is not in the lookup table, the frame is flooded on all ports
except the ingress port.
When the destination MAC address is present in the lookup table, the frame is switched only to
the correct egress port.
When the destination MAC address is present in the lookup table, and the egress port is the
same as the ingress port, the frame is dropped.
If the Ethernet Frame Check Sequence (FCS) is incorrect, because the switch is in cut-through
mode, a correctly formatted Ethernet frame is sent out with an incorrect FCS.
If the Ethernet frame is too short, the frame is discarded and the error counter is incremented.
If the Ethernet frame is too long, the frame is discarded and the error counter is incremented.
Frames sent to a broadcast destination MAC address are flooded on all ports except the
ingress port.
When MAC address entries in the lookup table time out, they are removed. In this event, frame
forwarding changes from unicast to flood.
An existing MAC address entry in the lookup table is discarded when a device is moved to a
new location. When a device is moved, the ingress frame from the new port causes the old
lookup table entry to be discarded and the new entry inserted into the lookup table. Frame
forwarding remains unicast to the new port.
When the lookup table is full, new entries replace the oldest MAC addresses after the oldest
MAC addresses age and time out. MAC addresses that still have traffic running are not timed
out.
NOTE
New entries start replacing older entries when the lookup table reaches 90 percent of its 32k
capacity.
VLAN tagging
The Dell FCoE hardware handles VLAN tagging as follows:
If the CEE port is configured to tag incoming frames with a single VLAN ID, then incoming
frames that are untagged are tagged with the VLAN ID.
If the CEE port is configured to tag incoming frames with multiple VLAN IDs, then incoming
frames that are untagged are tagged with the correct VLAN ID based on the port setting.
If the CEE port is configured to accept externally tagged frames, then incoming frames that are
tagged with a VLAN ID are passed through unchanged.
NOTE
Only a single switch-wide VLAN is capable of forwarding FCoE traffic.
For detailed information on configuring VLANs, see “Configuring VLANs Using the CEE CLI” on
page 31.